Search
Search
Asset Publisher
Content with Organisation AIT .
PI Controller - short description
Short Description This control function implements a complex control strategy based on an optimization approach. It is responsible for controlling electric biolers installed in a distributed...
Results of Simulation of Electric Boiler Use Excess Power - description
Short Description of Simulation Results The weights ai in the objective function where tuned such that the reference signal for the electric boiler power is tracked nearly perfectly while...
Results of Simulation of Electric Boiler Use Excess Power - long description
Results Description of Simulation -- Electric Boiler Use Excess Power As the MPC is considered to run every 15 minutes for a whole year, only two representative days are shown here. For...
Simulation of Electric Boiler Use Excess Power - data
Simulation Input Test Data Link to test data: Here Storage of Data: SmILES data format Test System Model used for Simulation: Electric Boiler Use Excess...
Simulation of Electric Boiler Use Excess Power - setup
Simulation Setup & Configurations Author / organization: Benedikt Leitner / AIT Objective Function of Simulation: Operation costs for a thermal-electric unit combined with a...
Simulation Results of COLLECTOPIA CROSS-SIMULATION (EIFER-EDF-AIT) - goals
Cross-Simulation Goals Goal of the Collectopia cross-simulation is to design the energy infrastructure of Collectopia in order to maximize the use of local energy (electricity from PV and...
Simulation Results of COLLECTOPIA CROSS-SIMULATION (EIFER-EDF-AIT) - setup
Simulation Setup & Configurations System Configuration: In a city in the North of France, the construction of an eco-district aims at promoting the solutions for sustainable and...
Simulation Results of COLLECTOPIA CROSS-SIMULATION (EIFER-EDF-AIT) - workflow
Description of Tasks and Workflow In the Collectopia cross-simulation EIFER, EDF and AIT are merging their modelling and simulation expertise. EIFER specializes in designing districts, in...
Simulation Results of SMARTDORF CROSS-SIMULATION (AIT-EDF) - goals
Cross-Simulation Goals The methodological approaches for simulation and optimization developed by the two partners AIT and EDF differ on multiple levels. While EDF specializes in design...
Simulation Results of SMARTDORF CROSS-SIMULATION (AIT-EDF) - setup
Simulation Setup & Configurations System Configuration: Smartdorf reflects the virtual energy situation of a fictional rural village in Austria. It is hosting a small number of...
Simulation Results of SMARTDORF CROSS-SIMULATION (AIT-EDF) - workflow
Description of Tasks and Workflow The practical realization of the PreCISE approach is described in Fig. 2. In the exchange phase, AIT extracts the relevant information for modelling...
SmartDorf - description
Short Description SmartDorf is a fictional village or part of a small town with a structure typical for the rural area of Austria. It is hosting a small number of residential homes, offices...
SmartDorf - details
System Configurations Details Meta Data Date 22-05-18 Version 1.0. Description ...
SmartDorf - overview
System Configuration Overview Author: Benedikt Pesendorfer (AIT) Key figures: Total annual electricity demand: ~ 500 [MWh/a] Total annual heat demand: ~ 1200 [MWh/a] Area:...
THERMAL ENERGY STORAGE - model overview
Model Overview Author / organization: Benedikt Leitner / AIT Domain: Thermal storage Intended application: Return-supply connections in, e.g., district heating networks and...
THERMAL ENERGY STORAGE- description
Short Description A model of a stratified storage tank for thermal energy storage. Intended to be used for return-supply connections in, e.g., district heating networks and possibly in...
ThermalEnergyStorage Component Model implementation - overview
ThermalEnergyStorage Component Model Implementation - Overview Author / organization: Benedikt Leitner / AIT Used Compoent model specification: Thermal Energy Storage Specification ...
ThermalEnergyStorage Component Model implementation - short description
Short Description A model of a stratified storage tank for thermal energy storage. Present use / development status The model is part of AIT’s internal Modelica library for...
UC4 – Network‐optimized use of DER - description
Short Description This use case describes a multi‐energy management system (M‐EMS) of a hybrid thermal‐electrical distribution network. The electrical distribution system is thereby connected...
— 20 Items per Page